Nortel Networks Video Gaming Accessories 553-3001-211 Manual De Usuario

Descargar
Página de 896
 NT1R20 Off-Premise Station Analog Line card
 Page 163 of 894
Port-to-port loss configuration
The loss plan for the NT1R20 OPS analog line card determines port-to-port 
loss for connections between an OPS analog line card unit (port) and other 
ports.
The transmission properties of each line unit are characterized by the OPS or 
ONS class of service assigned in the Analog (500/2500-type) Telephone 
Administration program LD 10.
The OPS analog line card provides transmission loss switching for control of 
end-to-end connection loss. Control of loss is a major element in controlling 
transmission performance parameters such as received volume, echo, noise, 
and crosstalk. The loss plan for the OPS analog line card determines 
port-to-port loss for connections between an OPS analog line card unit (port) 
and other IPE ports. LD 97 is used to configure systems for port-to-port loss. 
See Software Input/Output: Administration (553-3001-311) for LD 97 
service change instructions.
Electrical specifications
This section lists the electrical characteristics of the NT1R20 OPS analog line 
card. 
Circuit power
The +8.5 V dc input is regulated down to +5 V dc for use by the digital logic 
circuits. All other power to the card is used by the line interface circuits. 
The ±15.0 V dc inputs to the card are used to power the analog circuits. The 
+5 V dc from the module power supply is used for the analog hybrid. The 
–48.0 V dc input is for the telephone battery. Ringing power for telephones is 
86 Vrms ac at 20 Hz on –48 V dc. The Rsync signal is used to switch the 
20 Hz ringing on and off at the zero cross-over point to lengthen the life of 
the switching circuits.