 NT5D11 and NT5D14 Lineside T1 Interface cards
Installation
This section describes how to install and test the lineside T1 card.
When installed, the lineside T1 card occupies two card slots. It can be 
installed into an NT8D37 IPE module. 
When installing the lineside T1 card into NT8D37 IPE module, determine the 
vintage level module. If the 25-pair I/O connectors are partially split between 
adjacent IPE card slots, the lineside T1 card works only in card slots where 
Unit 0 of the motherboard card slot appears on the first pair of the 25-pair I/
O connector. 
7
Daisy-chaining to MMI
On = Yes
Off = No
8
MMI Master or Slave
On = Master
Off = Slave
Table 78
Lineside T1 card – CPE or CSU distance dip switch settings (Switch S2, positions 3 – 5)
Distance
S2 Switch
Position 3
S2 Switch
Position 4
S2 Switch
Position 5
0–133
On
Off
Off
134–266
Off
On
On
267–399
Off
On
Off
400–533
Off
Off
On
534–655
Off
Off
Off
Table 77
Lineside T1 card – T1 Switch 2 (S2) dip switch settings (Part 2 of 2)
Dip Switch 
Number
Characteristic
Selection