 NT5D11 and NT5D14 Lineside T1 Interface cards
 Page 215 of 894
framer slip seconds
loss of frame seconds
It retains the T1 performance statistics for the current hour, and for each hour 
for the previous 24 hours. Descriptions of each of these performance error 
counters, and instructions on how to report on them and clear them can be 
found in “Performance counters and reporting” on 
.
T1 verification and fault isolation testing
The MMI performs various tests to verify that the T1 is working adequately, 
or help to isolate a problem to the lineside T1 card, the T1 link, or the CPE 
equipment. Descriptions of all of these tests and instructions on how to run 
them can be found in “Testing” on 
Login and password
The MMI can be accessed through a TTY, a PC running a terminal emulation 
program, or a modem. After installing the MMI terminal and card cables, the 
MMI firmware can be accessed. 
For single card installations, log in by entering:
L<CR> 
For multiple card installations connected in a daisy-chain, log in by entering:
L <address> 
where the four-digit address is the two-digit address of the IPE shelf as set by 
dip switch positions (dip switch #1, positions 3-6) on the card (as opposed to 
the address set in the CS 1000 Release 4.0 software), plus the two-digit 
address of the card slot that the motherboard occupies. For example, to login 
to a card located in shelf 13, card slot 4, type: 
L 13 4 <CR> 
A space is inserted between the login command (L), the shelf address, and the 
card slot address.