Nortel Networks Video Gaming Accessories 553-3001-211 Manual De Usuario

Descargar
Página de 896
Page 224 of 894
 NT5D11 and NT5D14 Lineside T1 Interface cards
The “Disable Self-Clearing” option causes the system to continue the alarm 
condition until the Clear Alarm (C A) command set is entered. Line 
processing and the yellow alarm indication to the CPE is terminated as soon 
as the alarm condition clears, even if “Disable Self-Clearing” is set.
Display Configuration
The Display Configuration (D C) command set displays the various 
configuration settings established for the lineside T1 card. Entering the 
Display Configuration (D C) command set causes a screen similar to the 
following to appear:
LTI S/N 1103 Software Version 1.01    3/03/95 1:50
Alarms Enabled: YES
Self Clearing Enabled: YES
Alarm Level 1 threshold value: E-7      Threshold duration 
(in seconds): 10
Alarm Level 2 threshold value: E-5      Threshold duration 
(in seconds): 1
Frame slips alarm level threshold: 5    Threshold duration 
(in hours): 2
Current dip switch S1 settings (S1..S8) On Off Off On Off 
Off Off On
Current dip switch S2 settings (S1..S8) On Off On Off Off 
Off On Off
Alarm operation and reporting
The MMI monitors the T1 link according to the parameters established 
through the Set Alarm command set for the following conditions:
Excessive bit error rate
Frame slip errors
Out of frame condition
Loss of signal condition
Blue alarm (AIS) condition