Nortel Networks Video Gaming Accessories 553-3001-211 Manual De Usuario

Descargar
Página de 896
 NT5K21 XMFC/MFE card
 Page 361 of 894
Sender and receiver mode
The XMFC/MFE circuit card provides the interface between the system’s 
CPU and the trunk circuit which uses MFC or MFE signaling.
The XMFC/MFE circuit card transmits and receives forward and backward 
signals simultaneously on two channels. Each channel is programmed like a 
peripheral circuit card unit, with its own sending and receiving timeslots in 
the network.
Receive mode
When in receive mode, the XMFC/MFE card is linked to the trunk card by a 
PCM speech path over the network cards. MFC signals coming in over the 
trunks are relayed to the XMFC/MFE card as though they were speech. The 
XMFC/MFC card interprets each tone pair and sends the information to the 
CPU through the CPU bus.
Send mode
When in send mode, the CPU sends data to the XMFC/MFE card through the 
CPU bus. The CPU tells the XMFC/MFE card which tone pairs to send and 
the XMFC/MFE card generates the required tones and sends them to the trunk 
over the PCM network speech path. The trunk transmits the tones to the far 
end.
5
900 Hz + 1300 Hz
6
1100 Hz + 1300 Hz
7
700 Hz + 1500 Hz
8
900 Hz + 1500 Hz
9
1100 Hz + 1500 Hz
10
1300 Hz + 1500 Hz
Table 137
MFE Frequency values (Part 2 of 2)
Digit
Forward direction
OG-Tx, IC-Rx
Backward direction