Nortel Networks Video Gaming Accessories 553-3001-211 Manual De Usuario

Descargar
Página de 896
 NT6D80 MSDL card
 Page 405 of 894
Manually controlled maintenance
Use manual maintenance commands found in the following programs to 
enable, disable, reset, get the status of, and perform self-tests on the MSDL 
card:
Input/Output Diagnostic Program LD 37
Program  LD 42
Link Diagnostic Program LD 48
PRI D-channel Diagnostic Program LD 96
For a complete discussion of these programs, refer to Software Input/Output: 
Administration
 (553-3001-311).
Note 1: Enter commands after the dot (.) prompt.
Note 2:  The “
x
” in the commands below represents the DNUM value of 
the card number.
Enabling the MSDL
Enter 
ENL MSDL x
 to enable the MSDL manually. If the MSDL base code 
has not been previously downloaded or if the card version is different from 
the one on the system disk, the software is downloaded and the card is 
enabled.
To force software download and enable the card, enter 
ENL MSDL x FDL
This command forces the download of the MSDL base code and the 
configured peripheral software even if it is already resident on the card. The 
card is then enabled.
To enable a disabled MSDL and its ports, enter 
ENL MSDL x ALL
. This 
command downloads all peripheral software (if required) and enables any 
configured ports on the card. This command can be issued to enable some 
manually disabled ports on an already enabled MSDL.