 NT7D16 Data Access card
 Page 435 of 894
Programing DAC for mode 1 in service change LD11
The DAC must be configured as R232 (the Autodial feature key is used for 
this mode). The DAC must not be configured as an Asynchronous Data 
Module (ADM) trunk.
Mode 2
This mode should be selected when the DAC is connected to a Hayes-1200 
modem for inbound and outbound modem pooling. This mode is created 
specially to resolve some problems that were encountered with this modem, 
namely, the auto-reset implementation. When this modem is operating in the 
auto-reset mode, it drives both RI and DCD ON as long as DTR is OFF. This 
problem was resolved by driving DTR ON in the idle state, and OFF for 0.2 
seconds, and then ON when an established call is dropped. The DAC also 
ignores the status of RI and DCD for approximately 2 seconds after a call is 
released to avoid false inbound call initiation.
Configuring Hayes 1200 for mode 2
To configure this modem, set the following parameters in LD11:
DEM
DTE
PRM
OFF
DTR
ON
HOT
OFF
To configure this modem, set the configuration switches as follows:
switches 3, 8, and 10 to DOWN position
all other switches to UP position. Switch 7 should be UP when using 
RJ-11 jack.
Programing DAC for mode 2 in service change LD11
When used for inbound or outbound Modem Pool only, the DAC can be 
configured as R232 in LD11. When used for both inbound and outbound 
Modem Pool, the DAC must be configured as R232. When the DAC is 
programmed as station hunting, outbound modem access should be in the 
opposite direction to the 500/2500 station hunting for the inbound modem 
access.