Nortel Networks Video Gaming Accessories 553-3001-211 Manual De Usuario

Descargar
Página de 896
 NT8D41AA Serial Data Interface Paddle Board
 Page 665 of 894
Software service changes
Once the NT8D41 SDI paddle board has been installed in the system, the 
system software needs to be configured to recognize it. This is done using the 
Configuration Record program LD 17. Instructions for running the 
Configuration Record program are found in Software Input/Output: 
Administration
 (553-3001-311). 
Some of the prompts that are commonly used when running the Configuration 
Record program LD 17, are shown in “LD 17 – Serial port configuration 
parameters.” on 
. These parameters must be set for each port if both 
ports are being used.
LD 17 – Serial port configuration parameters.
Prompt
Response
Description
REQ:
CHG
Change configuration
TYPE:
CFN
Configuration type
IOTB
YES
Change input/output devices
ADAN
NEW TTY x
NEW PRT x
Define a new system terminal (printer) port as device x, where 
x = 0 to 15.
CDNO
1–16
Use the SDI paddle board number to keep track of all ports.
DENS
DDEN
Double density SDI paddle board
USER
xxx
Enter the user of port x. The values that can be entered 
depend on the software being used. See the Software Input/
Output: Administration
 (553-3001-311) for details.
XSM
(NO) YES
Port is used for the system monitor.