Nortel Networks Video Gaming Accessories 553-3001-211 Manual De Usuario

Descargar
Página de 896
Page 74 of 894
 Overview
Electromagnetic interference 
The CS 1000S, CS 1000M, and Meridian 1 systems meet the requirements of 
FCC Part 15 and CSA C108.8 electromagnetic interference (EMI) standards 
as a class “A” computing device. To accomplish this, the SDI cables must exit 
the module through EMI filters on the I/O panel. 
Reliability
The Mean Time Between Failure (MTBF) for all SDI cards is 55 years at 
40°C and 29 years at 55°C.
Installation
To use a serial data interface card in a CS 1000S, CS 1000M, or Meridian 1 
system, first install the card in the system, and then configure the system 
software to recognize it. These steps are discussed in the following sections.
Instructions for cabling the serial data interface cards to the various system 
consoles and peripherals are found in Communication Server 1000M and 
Meridian 1: Large System Installation and Configuration 
(553-3021-210).
Configuring the system software
Once an SDI card has been installed in the system, the system software needs 
to be configured to recognize it. This is done using the Configuration Record 
program LD 17. Instructions for the Configuration Record program are found 
in Software Input/Output: Administration (553-3001-311). 
Maintenance
The following maintenance programs are used to maintain individual SDI 
asynchronous ports. The program used depends on the application of the port.
LD 37 Input/Output Diagnostics – Used for system terminal, printer, 
background terminal ports, and system monitor status.
LD 42 Call Detail Recording (CDR) Diagnostic – For checking CDR 
links and CDR system terminals.