 NTCK16 Generic Central Office Trunk cards
Electrical specifications
Power requirements
Table 251 shows the power requirements for the NTCK16AX and 
NTCK16BX generic Central Office trunk cards.
Note 1: Analog circuitry is powered with +/-12 V generated from
+/-15 V. The maximum current imbalance between the +/-15 V rails is 
100 ma per circuit pack.
Note 2:  8.5V is regulated to give 5 V.
Environmental specifications
Table 252 lists the environmental specifications of the NTCK16AX and 
NTCK16BX generic Central Office trunk cards.
Table 251
NTCK16 circuit card power requirements
Voltage
Idle Current
Active current
+15.0 V dc
(See 1)
170 ma
330 ma
-15.0 V dc
(See 1)
170 ma
249 ma
+8.5 V dc
(See 2)
101 ma
100 ma
+5.0 V dc
160 ma
322 ma
Table 252
NTCK16 circuit card environmental specifications (Part 1 of 2)
Parameter
Specifications
Operating temperature
10 to 45 degrees C
Operating humidity
20 to 80% RH (non-condensing)