Nortel Networks Video Gaming Accessories 553-3001-211 Manual De Usuario

Descargar
Página de 896
Page 796 of 894
 NTCK16 Generic Central Office Trunk cards
Detection limits 
Pulses detected by the NTCK16AX circuit card must be within the following 
limits:
Busy tone detect
Busy tone is sent by the Central Office to indicate the release of an established 
call. 
Detection limits
The NTCK16AX and NTCK16BX generic Central Office trunk cards can 
detect busy tone within the following limits:
Loss switching
The Generic XFCOT is based on the XFCOT design, which is using a static 
pad download algorithm by default for its loss plan.
The generic XFCOT has to be set explicitly to a Dynamic Pad Switching 
mode to make it compliant with the standard North American Dynamic Pad 
Switching mode.
Frequency
11 880 to 12 120 Hz
Level
105 to 1100 mVrms
Note: The pack should not be 
used to detect levels of 1100 
mVrms or greater a Tip and Ring, 
as this may result in noise. 
Pulse length
Dependent on PPID – see LD 14
Frequency
400 to 620 Hz
Level
–30 to 0 dBm
Cadence
.