Nortel Networks Video Gaming Accessories 553-3001-211 Manual De Usuario

Descargar
Página de 896
 NTDK20 Small System Controller card
 Page 809 of 894
The MG 1000S 10BaseT port can run in Normal mode or Survival mode. In 
Normal mode, the MG 1000S does not provide access to maintenance or 
alarm management.
External connections to the 10BaseT port are provided by a 15-pin connector 
located on the backplanes of the Call Server and MG 1000S systems.
MG 1000S/Expansion card slot assignment
The MG 1000S and MG 1000S Expansion contain physical card slots, 
numbered 1 to 10. See Figure 171 on 
When configuring the system, the physical card slot numbers must be 
transposed to “logical” card slot numbers. For example, to configure a card 
physically located in Slot 2 of the first MG 1000S, use logical Slot 12. To 
configure a card physically located in Slot 2 of the second MG 1000S, use 
logical Slot 22. See Table 256 on 
.