Nortel Networks Video Gaming Accessories 553-3001-211 Manual De Usuario

Descargar
Página de 896
Page 90 of 894
 Acceptance tests
Again, see “LD 38” in the Software Input/Output: Maintenance 
(553-3001-511) for detailed information on using this command.
7
End the session in LD 38:
****
End of Procedure
Digitone receiver cards
Procedure 3
Testing digitone receiver cards
Use this procedure to test a Digitone receiver (DTR) card, a DTR 
daughterboard, or the DTR function on the NT8D18 Network/DTR card.
Note: The DTR daughterboard connected to a QPC659 Dual Loop 
Peripheral Buffer card cannot be assigned when the IPE shelf is used in 
single loop mode.
1
Log into the system:
LOGI (password)
2
See if the Digitone receiver to be tested is disabled:
LD 34
STAT
The system responds with the terminal number (TN), or numbers, of any 
disabled Digitone receivers.
3
If the Digitone receiver is disabled, enable it:
ENLR l s c uloop, shelf, card, and unit numbers
4
Test the Digitone receiver:
DTR l s c uloop, shelf, card, and unit numbers
If the system response is other than OK, see the Software Input/Output: 
Administration
 (553-3001-311) to analyze the messages.
5
End the session in LD 34:
****
End of Procedure