NEXO
 
A
NALOGUE 
PSTD
 
C
ONTROLLERS
 
 
 
 
 
 
Low Z
1
2
3
Low Z
1
2
3
TDcontroller
Amplifier
Mixing Desk
1
2
3
1
2
3
+
-
+
-
+
-
+
-
Low Z
L
o
w Z
PE
PE
PE
Safety 
Ground
SHIELD
SHIELD
IN
OUT
 
CAUTION! 
This servicing instruction is for use by qualified service personnel only. To reduce the 
risk of electric shock, do not perform any servicing other than that contained in the 
operating instructions unless you are qualified to do so. 
8.3.5  Recommendations for wiring the sense lines 
The impedance of the sense inputs of the TDcontroller are high, so currents are low and therefore light 
duty cable can be used. If the TDcontroller is housed in the amplifier racks an unshielded cable may be 
used. 
If the TDcontroller is located remotely - at the mixing position - a shielded cable is recommended, 
without using the shield as a conductor. The cable must be well protected from public access, as it 
carries potentially dangerous amplifier voltage.  
When one of the channels is not being used and the corresponding sense line is disconnected, cross 
talk onto the inactive sense line may in some cases produce signals capable of causing the inadvertent 
illumination of the Sense LED on that channel; although this has no effect on the internal operation of 
the TDcontroller, it can be cured by short-circuiting the terminals of the inactive sense line. 
8.3.6  Recommendations for wiring the audio outputs 
The output stages can drive several amplifiers in parallel; however it is not advisable to work with loads 
of less than 1kOhm(and strictly forbidden to drive less than 600Ohms
). It is best to check the 
impedance characteristics of the amplifier inputs - supplied by the manufacturer - to check how many 
amplifier channels can be paralleled. Where precise information is not available (and taking 10kOhm as 
the minimum value possible), ten channels in parallel per output is a sensible maximum. 
8.3.7 Electromagnetic 
environments 
 
The emission (this word describes all types of electromagnetic noise radiated by the equipment) 
requirements which have been applied to Nexo’s TDcontrollers are the stringent requirements of the 
”Commercial and light industrial environment” of the product family EMC standard for emission. 
The immunity (this word describes the ability to cope with electromagnetic disturbance generated by 
other items and natural phenomena) requirements that we have considered exceed those applicable to 
the ”Commercial and light industrial environment” of the product family EMC standard for immunity. In 
order to provide a further safety margin, we recommend that you do not operate the TDcontrollers in the 
presence of electromagnetic interference exceeding half of the limits found in this standard. 
These two EMC standards are those 
applicable to pro-audio equipment for the 
implementation of the ”EMC directive”. 
8.3.8  Analogue signal cables 
Analogue signals should be connected to the 
input and output ports of the TDcontroller via 
shielded twisted pair or starquad cable fitted 
with XLR connectors on the TDcontroller side. 
We recommend the use of low transfer 
impedance cables with a braided shield and a 
transfer impedance below 10 mΩ/m. For the 
sense inputs, the noise requirements are not 
as stringent, and any kind of twisted pair cable 
will be adequate.  
The TDcontroller is intended to be used with 
symmetrical (balanced) sources (for instance a mixer) and symmetrical loads (for instance a power 
amplifier (see figure). You can see that the TDcontroller provides a low impedance path between pin 1 
of its XLR connectors and its chassis. The TDcontroller can sustain high current in pin 1 without