Chapter 2
Function Reference — CTR_Config
NI-DAQ FRM for PC Compatibles
2-90
©
 National Instruments Corporation
CTR_Config
Format
status = CTR_Config (deviceNumber, ctr, edgeMode, gateMode, outType, outPolarity)
Purpose
Specifies the counting configuration to use for a counter.
Parameters
Input
Parameter Discussion
ctr is the counter number.
Range:
1, 2, or 5 for an MIO device except the E Series devices.
1 through 10 for a PC-TIO-10.
edgeMode indicates which edge of the input signal that the counter should count. edgeMode 
must be either 0 or 1.
0:
counter counts rising edges.
1:
counter counts falling edges.
gateMode selects the gating mode to be used by the counter. There are eight different gating 
modes. Each gating mode has been assigned a number between zero and 7. The available 
gating modes are as follows:
0:
No gating used.
1:
High-level gating of counter ctr used.
2:
Low-level gating of counter ctr used.
3:
Edge-triggered gating used—rising edge of counter ctr.
4:
Edge-triggered gating used—falling edge of counter ctr.
5:
Active high on terminal count of next lower-order counter.
Name
Type
Description
deviceNumber
i16
assigned by configuration utility
ctr
i16
counter number
edgeMode
i16
count rising or falling edges
gateMode
i16
gating mode to be used
outType
i16
type of output generated
outPolarity
i16
output polarity