Chapter 2
Function Reference — DAQ_Set_Clock
NI-DAQ FRM for PC Compatibles
2-134
©
 National Instruments Corporation
DAQ_Set_Clock
Format
DAQ_Set_Clock (deviceNumber, group, whichClock, desiredRate, units, actualRate)
Purpose
Sets the scan rate for a group of channels (DSA devices only).
Input
Output
Parameter Discussion
whichClock indicates the type of clock. 
0:
scan clock.
desiredRate is the rate at which you want data points to be sampled by the ADC(s).
units determines how desiredRate and actualRate are interpreted:
0:
points per second.
1:
seconds per point.
actualRate is the rate at which the ADCs produce samples. The capabilities of your device 
will determine how closely actualRate matches desiredRate. The DSA devices use the same 
base clock for both
 
DAQ/SCAN
 
and 
WFM
 operations so the rates available for a 
DAQ/SCAN 
will 
be restricted if a 
WFM
 
operation is already in progress.
Note
C programmers—actualRate is a pass-by-reference parameter.
Name
Type
Description
deviceNumber
i16
assigned by configuration utility
whichClock
u32
only scan clock supported
desiredRate
f64
desired rate in units
units
u32
ticks/second or seconds/tick
Name
Type
Description
actualRate
f64