Chapter 2
Function Reference — DIG_SCAN_Setup
©
 National Instruments Corporation
2-189
NI-DAQ FRM for PC Compatibles
dir selects the direction, input or output, to which the group is to be configured.
0:
Port is configured as an input port (default).
1:
Port is configured as an output port.
2:
Port is configured as a bidirectional port.
The following ports can be configured as bidirectional:
Using This Function
DIG_SCAN_Setup
 configures the specified group according to the specified port assignment 
and direction. If groupSize is 0, NI-DAQ releases any ports previously assigned to group
Any configurations not supported by or invalid for the specified group return an error, and 
NI-DAQ does not change the group configuration. NI-DAQ subsequently writes to or reads 
from ports assigned to a group as a group using 
DIG_Block_In
 and 
DIG_Block_Out
NI-DAQ can no longer access any ports assigned to a group through any of the non-group 
calls listed previously.
Because each port on the DIO-24, AT-MIO-16D, AT-MIO-16DE-10, and Lab and 1200 Series 
devices has its own handshaking circuitry, extra wiring might be necessary to make data 
transfer of a group with more than one port reliable. If the group has only one port, no extra 
wiring is needed.
Each input port has a different Strobe Input (STB*) control signal.
PC4 on the I/O connector is for port 0.
PC2 on the I/O connector is for port 1.
Each input port also has a different Input Buffer Full (IBF) control signal.
PC5 on the I/O connector is for port 0.
PC1 on the I/O connector is for port 1.
Each output port has a different Output Buffer Full (OBF*) control signal.
PC7 on the I/O connector is for port 0.
PC1 on the I/O connector is for port 1.
Device
Ports
AT-MIO-16D
2
AT-MIO-16DE-10
2
Lab and 1200 Series devices
0
DIO-24
0
DIO-96
0, 3, 6, and 9