Chapter 2
Function Reference — Init_DA_Brds
NI-DAQ FRM for PC Compatibles
2-262
©
 National Instruments Corporation
Of all these defaults, you can alter only the analog input and analog output settings of the 
non-E Series MIO and AI devices, Lab-PC+, and PC-LPM-16 devices by setting jumpers on 
the device. If you have changed the jumpers from the factory settings, you must call either 
AI_Configure
 and/or 
AO_Configure
 after 
Init_DA_Brds
 so that the software copies of 
these settings reflect the true settings of the device.
If any device resources have been reserved for SCXI use when you make a call to 
Init_DA_Brds
, those resources will still be reserved after you make the function call. 
Refer to Chapter 12, SCXI Hardware, in the DAQ Hardware Overview Guide for listings 
of the different device resources that can be reserved for SCXI.