Chapter 2
Function Reference — SCXI_Load_Config
NI-DAQ FRM for PC Compatibles
2-344
©
 National Instruments Corporation
SCXI_Load_Config
Format
status = SCXI_Load_Config (SCXIchassisID)
Purpose
Loads the SCXI chassis configuration information that you established in the configuration 
utility. Sets the software states of the chassis and the modules present to their default states. 
This function makes no changes to the hardware state of the SCXI chassis or modules.
Parameters
Input
Using This Function
It is important to realize that this function makes no changes to the hardware. To reset 
the hardware to its default state, you should use the 
SCXI_Reset
 function. Refer to the 
SCXI_Reset
 function description for a listing of the default states of the chassis and 
modules.
It is possible to change the configuration programmatically that you established in the 
configuration utility using the 
SCXI_Set_Config
 function.
Name
Type
Description
SCXIchassisID
i16
logical ID assigned to the SCXI chassis