National Instruments Welding System 321645c-01 Manual De Usuario

Descargar
Página de 554
Chapter 2
Function Reference — SCXI_Track_Hold_Control
©
 National Instruments Corporation
2-367
NI-DAQ FRM for PC Compatibles
SCXI_Track_Hold_Control
Format
status = SCXI_Track_Hold_Control (SCXIchassisID, moduleSlot, state, DAQdeviceNumber)
Purpose
Controls the track/hold state of an SCXI-1140 module that you have set up for a 
single-channel operation.
Note
This function is not supported for the E Series devices.
Parameters
Input
Parameter Discussion
moduleSlot is the chassis slot number of the SCXI-1140 module you want.
Range:
1 to n, where n is the number of slots in the chassis.
state indicates whether to put the module into track or hold mode.
0:
Put the module into track mode.
1:
Put the module into hold mode.
DAQdeviceNumber is the device number of the DAQ device that will perform the channel 
scanning operation. If you are using the SCXI-1200 to perform the data acquisition, you 
should specify the module logical device number. 
Using This Function
Refer to the SCXI Application Hints discussion in Chapter 3, Software Overview, of the 
NI-DAQ User Manual for PC Compatibles for information about how to use the SCXI-1140 
for single-channel and channel-scanning operations. This function is only needed for 
single-channel applications; the scan interval timer controls the track/hold state of the module 
during a channel-scanning operation. The NI-DAQ User Manual for PC Compatibles 
contains flowcharts for single-channel operations using the SCXI-1140 and this function.
Name
Type
Description
SCXIchassisID
i16
logical ID assigned to the SCXI chassis
moduleSlot
i16
chassis slot number
state
i16
track or hold mode
DAQdeviceNumber
i16
device number of the DAQ device used to read 
the input channel