Function Reference — WFM_Load
©
National Instruments Corporation
2-433
NI-DAQ FRM for PC Compatibles
changing the jumpers on the device, you must call
AO_Configure
to set the software copies
of the settings prior to calling
WFM_Group_Control
(operation = START). You can make
repeated calls to
WFM_Load
to change the shape of a waveform in progress, except on E Series
devices and SCXI DAQ modules used with remote SCXI; if you make repeated calls using
these devices, this function will return a transferInProgError. You also must use the
parameter values for numChans and chanVect used in the call to
these devices, this function will return a transferInProgError. You also must use the
parameter values for numChans and chanVect used in the call to
WFM_Load
prior to starting
the waveform when making calls to
WFM_Load
while a waveform is in progress.
(AT-MIO-16F-5 only) If your buffer has been aligned by a previous call to
Align_DMA_Buffer
,
WFM_Load
automatically indexes into the buffer to the new starting
point of the data. If you call
WFM_Load
with a new buffer while a waveform generation is in
progress, NI-DAQ unaligns the previous buffer when the function returns.
The DSA devices use 32-bit data buffers. If you are using C or Delphi, you will need to type
cast your i32 array to i16 when you call
cast your i32 array to i16 when you call
WFM_Load
. If you are using Visual Basic, you should
use the
nidaqr32.bas
file (instead of
nidaq32.bas
) to relax type checking on buffer. The
DSA devices use the upper 18 bits of each buffer element. The lower 14 bits are ignored and
you should set them to zero.
you should set them to zero.