National Instruments NI 1450 Series Manual De Usuario

Descargar
Página de 83
Chapter 4
Digital I/O Functionality
© National Instruments Corporation
4-11
Overheat
Operating the NI 1450 outside of its temperature specifications may cause 
the NI 1450 to overheat. Refer to Appendix B
temperature specifications.
In the event of an overheat, all NI 1450 operation halts and the 
POWER OK LED turns red. If Shutdown mode is enabled, the outputs 
go to the user-defined shutdown states.
Considerations When Connecting the Digital I/O
The isolated trigger inputs on the NI 1450 are current sinking and optically 
isolated. Figure 4-6 shows the trigger input interface circuit. 
Wiring an Isolated Input to a Sourcing Output Device
You can wire an isolated input to a sourcing output device, as shown in the 
example in Figure 4-5. Refer to Appendix B, 
 for switching 
thresholds and current requirements.
Caution
Do not apply a voltage greater than 30 VDC to the isolated inputs. Doing so could 
damage NI 1450.
Table 4-4.  Configuration Settings and Effects
Fault 
Condition
Configuration Settings
Configuration Effects
Safe Mode 
DIP
Shutdown 
Enabled
Processing Halts
Outputs Change to 
User-Defined States
External 
Shutdown 
On
N/A
N/A
No
Off
On
Yes
Yes
Off
Off
No
No
Watchdog
On
N/A
N/A
No
Off
On
Yes
Yes
Off
Off
Yes
No
Overheat
On
N/A
Yes
No
Off
On
Yes
Yes
Off
Off
Yes
No