Kuma Stoves SHASTA Manual De Usuario

Descargar
Página de 12
 
CONTENTS 
 
 
Section 1– Stove placement, air requirements, and clearances….. pg. 1-2 
 
 
 
  2– The flue and flue connections………………………... pg. 2-3 
 
 
 
  3– Fuel tank installation and fuel line connections……… pg. 3-4 
 
 
 
  4– Lighting, adjustments to carburetor, and draft 
 
 
          stabilizer adjustments………………………………. pg. 4-7 
 
 
 
  5– Servicing……………………………………………..  pg. 7-8 
 
 
 
  6– Trouble-shooting guide……………………………..... pg. 8-9 
 
 
 
  7– Fireplace installation instructions………….………… pg. 10 
 
 
 
  8-  Warranty………………………………………………pg. 11 
 
SECTION 1 
Stove placement, air requirements, and clearances 
 
 
Try to pick a location that will be somewhat central in the house or room in which you 
wish to install the Shasta.  Due consideration of the fuel tank location, ease of fuel line 
installation, and flue location is wise.  You will want to read the fuel tank section to get a better 
idea of where to locate the tank as well as the stove.  The stove must be placed on hearth that is 
non-combustible, having a thickness of 3/8” or greater.  A 24”x30” minimum hearth pad area is 
recommended.  Once a location is established, the stove can be placed on the hearth and 
leveled.  It is absolutely imperative that your stove is level.  There are adjustment bolts under 
each corner of the pedestal base should these adjustments be necessary, or if a leg set is used, 
there are adjustment bolts on each leg.  Place a level on top of the pedestal base both directions 
and adjust until level. 
 
This unit has been tested to U.L. 896 and 307A by Omni Test Laboratories and is 
approved for installation and use in manufactured homes.  There are some special 
considerations when installing into a mobile or manufactured home.  The flue system must 
consist of a 4” diameter CLASS “L”, U.L. 641 type insulated chimney, and either a 4” single or 
double-wall stove pipe connector.  A CLASS “A” metal chimney or a masonry chimney may be 
used, but must have a 4” stainless steel liner.   Dura-Vent Pellet Vent (4”) may be used as either 
a connector or chimney or both. The manufactured home installation also requires an outside 
combustion air source.  If outside air is accessed through the floor, a 4” diameter or larger duct 
should be installed through the hearth and floor, extending past the insulation barrier on the 
underneath side of the home.  Make sure there is a rodent screen with a maximum 1/4” x 1/4” 
opening placed over the duct opening to prevent rodents from accessing the stove bottom.  A 
standard outside air (dryer-vent type) kit may be used or an outside air kit (#4OAVK) may be 
obtained from your dealer.