AI232 Version 9.6x User’s Guide
Link Configuration: General Link Properties Configuration
5-18
This ModMux link example displays 
08 Auto Disable Error Limit
 set to 
25000
.
Configuration in the AI232 Local Menu System
1. Access the Link Menu.
2. Select 
Auto Disable Menu
. The Link Auto Disable Menu appears.
3. For 
Errors/second limit for auto disable
, enter the error limit value. The default 
is 
0
.
This example displays 
Errors/second limit for auto-disable
 set to 
25000
.
Flow Control
Description
This menu item enables a receiving device to tell a sending device to stop sending 
data when data is coming too fast and to start sending data when the receiver is 
ready.
There are two available flow control options for AI232:
z
None
—Specifies no flow control.
z
XonXoff
—Specifies the flow control option that uses standard ASCII control 
characters to tell a sending device to stop or resume data transmission.
Menu Item Type
Toggle
Link Type Availability
Async, AsyncPPP, and ModMux
>8,25000
                                                                 Menu 4.2.14.12
01 Link Number (1-32)--------------------------------------------------------01
02*Link Type (Async, AsyncPPP, ModMux)---------------------------------  ModMux
03 Link Description------------------------------                  Async link 1
04*Link state (Enabled, Disabled)-------------------------------------- Enabled
05+Port speed------------------------------------------------------------- 9600
06*Flow Control (None, XonXoff)-----------------------------------------   None
07 Xon Repeat interval (0 - 120s with 0 = no repeat)------------------------000
08 Auto Disable Error Limit (0-1000000)---------------------------------0025000
Link Auto Disable Menu
Link being configured  . . . . . . . . . . . . . . . . . . . . . . . . .    03
Errors/second limit for auto-disable  . . . . . . . . . . . . . . . . . . 25000