Kärcher 600 CD Manual De Usuario

Descargar
Página de 93
33
WTC 600 LP / MP
OPERATION  OF THE  SYSTEM
Service Handbook 08.2004
Position
Indication
Description
6
Covered pushbutton
0000.
Without function
7
Covered pushbutton
0000.
Without function
8
Covered pushbutton
AA14
Without function
9
Covered pushbutton
AA02
10
Covered pushbutton
AA02
11
TIME OF DAY
1C10
Backwashing period 10 minutes
12
Covered pushbutton
2C00
0 minutes
13
Covered pushbutton
3C00
0 minutes
14
Covered pushbutton
4C03
Initial filtration 3 minutes
15
Covered pushbutton
4d10
Leave programming mode
Table 18
Programming table
1)
 for media filter and activated carbon filter
1)
For changing of any given value from the programming table, the complete menu must be run
through. The enter position flashes and the value is changed with the ”ADVANCE“ pushbutton!
Indication
Description
02.30
Day time
F-00
Days since the last regeneration
0.0.0.0.
Number of regeneration
Table 19
Statistical indications – diagnosis
Briefly pressing the “ADVANCE” pushbutton after selecting runs you through the
diagnosis indication.
NOTE