Motion 42-02-S028 Manual De Usuario

Descargar
Página de 20
Security Password Default for IMC Connections
13
Security Password Default for IMC Connections
If the USN is connected to an IMC controller with the CRT Security feature enabled, the USN 
will allow iMonitor software to configure security parameters.  In order to configure security 
parameters, a user must log into the controller using a password.  This password is stored on 
the USN board.
The default password is “manager”. 
If it is lost, the password can be reset back to default:
1. Disconnect the serial communication cable from the USN.
2. Change the Device type setting from Swing Panel to a non-swing panel type (e.g.  PCA 
Simplex A2K) and save.
3. Reset board by pressing the RSTA button.
4. Change Device type back to Swing Panel and save.
5. Remove power from USN.
6. Reconnect serial communication cable.
7. Reconnect power to USN.
KCE Functionality
In order to utilize car recall functionality with iMonitor software, the KCE (Keyboard Control 
for Elevators) feature must be enabled on the controller.  
On PCA-type controllers, activate KCE from the Extra Features menu.  Please consult the 
appropriate controller documentation for details.
On IMC-type controllers, the KCE feature must be pre-programmed on the controller software.  
You can verify the presence of the KCE feature by connecting to the group controller using a 
CRT, terminal emulator or TigerTerm software.  Go to the Job Configuration screen (F6) and 
view the Other Options menu item.  Please consult the appropriate controller documentation 
for more details.
Note
KCE functionality is available on only certain MCE controllers. Check the controller user man-
ual.