Motorola Stud Sensor 3.1 Manual De Usuario

Descargar
Página de 39
Mesh Enabled Architecture 
 
Geo-Location Reference Guide 
7  
Alert Window 
The Alert Window displays certain events that may occur while the system is operating. These 
events are summarized by Event TimeMAC AddressName, and the Status
You can choose to either enable or disable display this window by selecting the Alert 
Window option under the Window menu. 
 
 
Figure 9. 
Alert Window 
 
Alert Parameter 
Description 
Event Time 
The date and time stamp for when the event that triggered the 
alert was captured. 
MAC Address 
The MAC address for the device being monitored. 
Name 
The name of the network node being monitored. The name 
displayed here will vary depending on the display attributes 
selected. The default display parameter is the MAC address 
formatted to remove hyphenation. 
Status 
The current status of the sensor device. One of the following 
Alert Status messages will be displayed: 
New Sensor Detected
 – Additional configuration parameters 
have been applied and a sensor has been detected and added 
to the network configuration. The device name will migrate 
from the Unconfigured Sensors folder to the appropriate 
network configuration folder in the Sensor ID Window. 
Sensor is On-Line
 – A sensor device that is currently 
configured in the network is on-line. 
Sensor is Off-Line
 – A sensor device that is currently 
configured in the network is off-line. 
Sensor is Dead
 – Communications cannot be established with 
a sensor device that is currently configured in the network.