18.4  EMC Immunity Compliance – Europe Only 
Top-level Specification ETSI 301-489.  
Specification 
 
Comment 
 
EN 55082-1 Generic EMC and EMI 
requirements for Europe 
 
EN 61000-4-2: 1995 Electro Static 
Discharge (ESD), Class 2, 8 kV air, 4 kV 
contact discharge 
 
EN 61000-4-3: 1995 ENV50140: 1993 
(radiated immunity) 3 V/m 
 
EN 61000-4-4: 1995 (Bursts/Transients), 
Class 4, 4 kV level (power lines AC & DC) 
Signal lines @ 0.5 kV open circuit voltage. 
EN 6100045:1995, (Surge Immunity) 
Requires screened connection to users 
network 
EN 61000-4-6: 1996 (Injected RF), power 
line, Class 3 @ 10 V/m 
Signal lines, Class 3 @ 3 V RMS un-
modulated.