Motorola PTP 400 Series Manual De Usuario

Descargar
Página de 208
 
 
32
3.3.4  Remote LEDs and Recovery Switch 
The PTP 400 Series Bridge PIDU Plus provides a facility to connect remote LEDs and 
Recovery switch allowing the PIDU Plus to be mounted inside an enclosure. At the left end of 
the PIDU Plus under the ODU connection cover can be found three jumpers and a PCB 
header. Jumpers J906 and J907 should be removed and connection to the remote LEDs and 
Recovery switch made to J908 as shown in Figure 9. 
J905
J907
J906
J908
ODU
Connection
J905
J907
J906
J908
Remove links J906 and J907
Yellow Ethernet LED
Green Power LED
Recovery Switch
 
Figure 9 - Remote LED and Recovery Switch Wiring 
3.3.5  Cables and Connectors
 
 
The cable used to connect the PTP 400 Series PIDU Plus to the ODU can be any standard 
CAT 5 type provided that it is suitable for outdoor deployment. Motorola recommends that 
cables to the specification below be used.  
NEC/CEC: CMR (ETL) C (ETL) 75C SUN RES OIL RES II  
Failure to use the recommended (or equivalent) standard of cable may invalidate the 
system’s safety certification.  
The PIDU Plus/ODU cable may be unscreened (UTP) or screened (STP). However, 
unscreened cables reduce the system’s ability to cope with nearby lightning strikes. If 
lightning activity is common in the area of deployment, the use of screened cable is highly 
recommended. See Section 11 “Lightning Protection”.