MPC OM-20000072 Manual De Usuario

Descargar
Página de 102
22
MPC User Manual Rev 0D
Chapter 3
MPC Setup Considerations
3.2.4
Power
After initial connection of the power source to the receiver and pressing the power switch on the back 
of the unit (see Figure 3 on Page 19), the Power LED on the front of the MPC glows red.
The PWR button on the keypad is used to access the MPC Shutdown Type screen in the VFD menus, 
see Pages 45. Choosing REBOOT will cause the embedded PC to reboot. Choosing POWERDOWN 
will terminate the programs running on the embedded PC and cause the PC buffers to be flushed to the 
hard drive. The keypad will be unusable again until the power switch is turned off, then on, and the 
VFD is visible again.
The VFD display will screen-save and appear black after 5 minutes of inactivity. Hit any key on the 
VFD keypad for it to be restored.
The MPC requires an input supply voltage that comes from a normal power source of 110/220 volts at 
50/60 Hz AC through its 3-pin power connector. The MPC has an internal power module that does the 
following:
·
filters and regulates the supply voltage
·
protects against over-voltage, over-current, and high-temperature conditions
·
provides automatic reset circuit protection 
WARNING:
1.  Supplying the MPC with an input voltage that is below 100 VAC will cause 
the unit to suspend operation. An input voltage above 240 VAC may 
physically damage the unit.
 2.  Disconnect the power source before servicing the power connector’s 1.5 
Amp fuse.
The Power Input connector on the MPC contains a 1.5 Amp fuse that can be serviced as long as the 
MPC is disconnected from power.
As is also described on Page 42, the GPS row in the MPC System Status screen of the VFD menus 
provides information and error messages including any to do with voltage. Also, the RXHWLEVELS 
log, refer to Volume 2 of the OEM4 Users’ Guide, contains environmental and voltage parameters.
The data logging mechanism is designed to be robust and to endure power interruptions (and similar 
disruptive events) with minimum loss of data. In this situation, allow for your data to be possibly 
reduced by several seconds up to a maximum of a minute. To the extent possible, error messages 
attempt to describe the problem. If you require further information on this topic, please refer to the 
description of the RXSTATUS log in Volume 2 of the OEM4 Users’ Guide.
* The MPC is designed for continuous operation. However, if you need to power down the unit, it 
is recommended that you always use the MPC Shutdown Type menu, see Page 45. Then give the 
internal operating system a few minutes to flush its cache buffers to the hard drive, and turn off 
the power at the power switch.
For a listing of the required input supply voltages, see Appendix A, MPC Specifications on Page 77
For more information on the supplied 3-pin power cable, see A.4, Power Cable on Page 80.