Operating Options
Your Ravelle™ 42 gas fireplace comes equipped with an “On/Off” rocker 
switch used to turn the burner on and off while the pilot light is on. The 
switch is a round rocker switch located behind the lower door of the 
fireplace’s face.
A wall-mounted switch, a millivolt wall thermostat, or a remote control 
can be used to supplement the rocker switch. The gas valve is powered 
by millivolts generated by the pilot assembly. This millivolt system is 
very sensitive to electrical resistance, therefore make sure all connec-
tions are tight, clean and free from corrosion. Do not splice any millivolt 
wires. Consult the table on this page to determine the proper gage of 
wire for the thermostat or wall switch connections. This table refers to 
the total length of the wire (out to the switch and back). The thermostat 
must  be  a  millivolt  type.  A  24-volt  furnace  thermostat  will  not  work. 
Never hook up household current - 120 Volts - to the millivolt system. 
It is not recommended to hook up any more than two switches to the 
fireplace (for example a rocker switch and a wall thermostat). Additional 
switches may affect the system resistance and increase the chance of 
the burner not igniting.
Follow the instructions included with the thermostat or remote control 
for wiring. The thermostat, remote control and rocker switch will turn the 
burner on and off independently. Be sure to set the rocker switch to the 
“Off” position when using the thermostat or remote control and set the 
thermostat or remote control to the lowest temperature when you wish 
to use the rocker switch only, otherwise one may override the other.
Thermostat Wire
Wire Size
Maximum Length
12 Gage
100 Feet
14 Gage
64 Feet
16 Gage
40 Feet
18 Gage
25 Feet
20 Gage
16 Feet
Millivolt Control System
This fireplace operates on a millivolt control system. As such, no addi-
tional power supply is needed for the fireplace to heat. The pilot assembly 
contains a thermocouple, that when heated by the pilot flame, generates 
electricity (millivolts- mV=1/1000 of a volt) which opens a valve allow-
ing gas to flow to the pilot assembly. The pilot assembly also contains a 
thermopile, that when heated by the pilot flame, generates electricity that 
flows to terminal #1 (labeled THTP) on the gas valve. When the electricity 
is conducted from terminal #1 through the on/off switch, thermostat, 
or receiver of the remote control to terminal #3 (labeled TH) on the gas 
valve, the main burner will ignite.   
CAUTION:  Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous 
operation. 
ATTENTION:    Au  moment  de  l'entretien  des  commandes, 
étiquetez tous les fils avant de les débrancher.  Des erreurs 
de cáblage peuvent entraîner un fonctionnement inadéquat et 
dangereux.
Figure 47
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Millivolt Control Schematic
Sparker
Pilot Hood
ON/OFF Rocker Switch, Thermo-
stat, or Remote Thermostat
Pilot Assembly
Thermocouple
Piezo Igniter
White
Gas Inlet
Pilot Gas Line
Thermopile
Brown
Wiring Terminals
TH
TP
TH/TP