21.  Set the throttle lever to the idle position after closing the chemical valve if the sprayer 
is not to be used for more than one or two minutes.  However, do not allow the engine 
to idle for a prolonged period (see point 14 above). 
22.  To stop the engine, move the throttle lever to the fully closed position, and turn off the 
switch. 
23.  The entire sprayer, including the AU8000 sprayhead, must be thoroughly cleaned 
after use.  If ULV chemicals have been used, they must be removed with water or a 
suitable solvent such as kerosene.  Water is only suitable if water based formulations 
have been used.  Before cleaning the outside of the sprayer, the tank, hoses and 
sprayhead must be flushed out by spraying about 2 litres of water or solvent from the 
mistblower. 
 
4.2.  Operation of Sprayer with Chemical Pump 
This section applies only to sprayers fitted with the optional chemical boost pump. 
1.  Before starting the sprayer, ensure that the chemical valve lever is in the BOOST 
position and that the pump is DISENGAGED (see Fig. 2). 
2. 
Start the sprayer as described in section 4.1. 
3.  When in the spraying area, move the pump lever to the ENGAGED position and 
proceed as described in section 4.1. 
 
 
 
Fig. 2 – Controls for Pump and Suction Filling Valve