MAXX-2400HD Owner’s Manual 
Rack Mounting 
 
CAUTION! 
It is strongly recommended to rack mount the MAXX-2400HD before installing the drives. This will 
reduce the weight significantly, and simplify the mounting process. 
 
In North America, the rack slide rails will be mounted in a 19” rack enclosure having 10-24 or 
10-32 tapped holes.  In countries with metric standards, the user will need to supply appropriate 
fasteners. 
Install the included rack mount slide rails in the rack. They must be securely mounted at both 
the front and back of the rack. Extend the slides in the slide rails. Carefully mate them with the rails 
on the sides of the MAXX-2400HD – this process requires at least two people unless an adjustable 
lift is available. Slide the MAXX-2400HD into the rack. 
Deploy the front panel to expose the rack screw slots.  Unscrew the knurled fasteners and pull 
forward and down to deploy the front panel. Fasten the MAXX-2400HD into the rack using 
appropriate flat-head screws (#10 Phillips screws provided in North America).  Retract the front 
panel.  Tighten the front panel access screws.  
Cables attached to the rear of the MAXX-2400HD should be supported.  Do not suspend 
substantial cable weight from the server. 
Mounting an Audio Module (AXP-3, AXP-4 or DXP-1)  
An optional multi-channel audio module may also be rack mounted above or below the 
MAXX-2400HD, on the front or rear of the rack. Four elongated screw holes are provided to 
facilitate rack mounting of the AXP Module. Audio modules are connected to the server with the 
supplied 68 Pin cable. Connect one end to the mating connector on the rear of the audio module. 
Connect the other end to the rear panel of the server. 
Mounting the Control Module (CXP)  
The supplied CXP module may also be rack mounted above or below the MAXX-2400HD, on 
the front or rear of the rack. Four elongated screw holes are provided to facilitate rack mounting of 
the CXP Module. The CXP module is connected to the server using the supplied 68 Pin cable. 
Connect one end of the cable to the mating connector on the rear of the CXP Module. Connect
 
the 
other end to the rear panel of the server. Refer to  Figure 
5
 on page 28 for information about 
connecting GPI and automation signals to the CXP Module.