Hot Swapping 
Power Supplies 
The Series 5000 CardModules and Power Supplies 
are fully hot swappable in the event of a fault or 
failure. 
 
Power Supply Failure 
A failure in the Primary power supply will 
automatically trigger the use of the redundant 
supply (if fitted) and will trigger the following alarm 
conditions / indications(requires controller option). 
 
•  Reported fault on the monitoring system  
 
•  Alarm GPO trigger on the alarm connector (see 
Alarm Connections section) 
 
•  Front Panel LED (normally green) will go out (See 
Alarm / Status indication section) 
 
Once identified, the defective supply can be 
removed and replaced with power connected 
with no interruption to the operation of the 
CardModules. 
 
CardModules 
If a CardModule fails the error will be reported over 
the monitoring system and via the front side alarm 
LED. Alarm function is module dependant so please 
refer to the CardModule manual for failure 
conditions and indications. The defective 
CardModule can be removed and replaced with 
an identical replacement without removing power 
from the frame.