Parity Options
2-9
Asynchronous SCSI Send –
Step 1.
Look at the
and
registers and calculate if there are bytes left in the DMA FIFO.
To make this calculation, subtract the seven least significant bits
of the
register from the 7-bit value of
the
register. AND the result with 0x7F for
a byte count between zero and 80.
Step 2.
Read bit 5 in the
register to
determine if any bytes are left in the
register. If bit 5 is set in SSTAT0, then the SODL
register is full.
Synchronous SCSI Send –
Step 1.
Look at the
and
registers and calculate if there are bytes left in the DMA FIFO.
To make this calculation, subtract the seven least significant bits
of the
register from the 7-bit value of
the
register. AND the result with 0x7F for
a byte count between zero and 80.
Step 2.
Read bit 5 in the
register to
determine if any bytes are left in the
register. If bit 5 is set in SSTAT0, then the
register is full.
Step 3.
Read bit 6 in the
register to
determine if any bytes are left in the SODR register. If bit 6 is
set in SSTAT0, then the SODR register is full.
Asynchronous SCSI Receive –
Step 1.
Look at the
and
registers and calculate if there are bytes left in the DMA FIFO.
To make this calculation, subtract the seven least significant bits
of the
register from the 7-bit value of
the
register. AND the result with 0x7F for
a byte count between zero and 80.