Liebherr Oven liebherr Manual De Usuario

Descargar
Página de 12
GB
15
3.  Insert the bent section of the hose through 
the opening at the rear of the appliance.
4.  Connect the hose to the solenoid valve 
at the front side of the appliance.
5.  Route the mains cable towards the socket.
6.  Route the water hose towards the water shut-off valve.
   WARNING! 
Do not connect the appliance to the power supply until the 
installation is completed.
   CAUTION! 
Lay the mains cable and the water hose in such a way that 
they will not be damaged when the appliance is slid into 
the installation recess.
5.
6.
Anti-tipping bracket
Compressor mounting 
plate
Wall
Appliance
7.  Push the appliance slowly into the recess until the compressor 
mounting plate touches the anti-tipping bracket.
   WARNING! 
To prevent the appliance from tipping forwards, the compres-
sor mounting plate must be touching the anti-tipping bracket!
8.  Connect the hose to the shut-off tap.
  Open the shut-off tap and check the system for leakage.
Important!
After the ice maker has been switched on, the water supply system 
must be bled. See the section Bleeding the ice maker in the 
operating instructions.