ROUTINE MAINTENANCE
  
* Inspect your stove or insert at minimum frequency stated until you establish a minimum frequency required for 
your installation (frequency will vary depending upon fuel BTU value / ash content, usage, and misc. installation 
variables). 
 
 
Page 22 
ROUTINE CLEANING 
Note: Stove will need to be shut off and cooled enough to 
handle before routine cleaning is performed.  
Always disconnect power before doing any routine clean-
ing. 
 
The following areas need to be inspected and cleaned 
during routine cleaning: 
 
•  UltraGrate (burn grate) 
•  Ash Slide Plate  
•  Ash Pan 
•  Heat Exchange Tubes 
•  Photoeye 
•  Exhaust Passages and Vent Pipe 
•  Gaskets 
•  Window Wash 
•  Rear Stove Compartment 
 
UltraGrate
 (BURN GRATE) 
The UltraGrate
 should be inspected periodically to as-
sure that the air holes have not become clogged with ash 
or clinkers. The UltraGrate
 can easily be cleaned with 
the grate scraper / ash pan tool, or it can be removed for 
cleaning. It is very important to monitor the ash build up 
under the UltraGrate
, as excessive amounts of ash will 
block combustion air from entering the grate, causing 
pellets to pile-up in the grate. The ash build-up under the 
grate is easily dumped into the ash pan by pulling out the 
ash slide weekly as shown below. The grate cleaning 
procedure is the same for all models. 
  
UltraGrate
 
 
 
 
* (Recommended Frequency of 1 day – 2 weeks) 
 
ASH PAN  
The ash pan will have to be emptied periodically, de-
pending on amount of fuel consumed. The T300P Series 
ash pan is pulled straight out using the black pull knob 
located on the front of the ash pan (see following pic-
ture). 
  
Ash Pan 
 
 
 
* (Recommended Frequency of 2 days – 2 weeks) 
 
ASH SLIDE PLATE 
Ash that accumulates around the grate can be “dropped” 
into the ash pan without opening the firebox door. Simply 
pull open the ash release slide plate as shown in photo 
using the grate scraper tool provided. Remove the ash 
pan as shown. Note: Make sure to fully close the plates 
when finished. Failure to close the ash release slide 
plates completely may cause the fuel to burn poorly (due 
to reduced airflow through the grate), which may then 
cause pellets to “pile up” in the grate.  
 
Ash Slide Plate 
 
 
*(Recommended Frequency of 1 day – 2 weeks.)