HP Cell Phone Accessories 8935 Manual De Usuario

Descargar
Página de 77
42
Chapter 2 
Testing AMPS Base Stations
Receiver Sensitivity (SINAD)
Receiver Sensitivity (SINAD)
This test measures the receiver’s ability to demodulate voice signals 
from very low RF carrier levels.
Prerequisites
The following conditions must be met before testing:
❒ The Test Set is turned on and Preset was pressed to establish a 
known instrument state.
❒ You have configured the Test Set for channel tuning (
❒ You have specified any gains or losses in your test system (
Test Procedure
1. Turn off the base station’s transmitter.
2. Turn the base station’s radio squelch, data, and SAT off.
3. Connect the base station receiver’s inputs to the Test Set’s DUPLEX 
OUT port.
4. Connect the receiver’s audio output to the Test Set’s AUDIO IN 
port(s). Unless the receiver’s audio out amplifier is not referenced to 
chassis ground, you should only connect to the AUDIO IN - HI port. 
For floating output amplifiers, see the HP 8935 Reference Manual 
for information on using the AUDIO IN - LO connection.
5. Press 
CDMA Gen
 to access the CDMA GENERATOR screen.
Main Menu