2. Auxiliary Codes A-2 and Later
This diagnostic procedure is a sequence check that allows you to diagnose the electrical 
system and components. Before proceeding, check for correct installation, adequate 
water pressure (7 to 113 PSIG), and proper voltage per unit nameplate. When checking 
voltage (115VAC), always choose a neutral (W wire) to establish a good neutral 
connection.
1) Move the power switch to the "OFF" position, then unplug the unit from the electrical 
outlet.
2) Remove all ice from the storage bin.
3) Remove the rear panels.
4) Remove the clamp securing the drain plug, then lower the drain hose into a container. 
Remove the drain plug to drain the water from the evaporator assembly and reservoir. 
See Fig. 4.
5) After all of the water has drained, replace the drain hose, drain plug, and drain clamp in 
their correct positions. 
6) Remove the front panel and louver. Remove the screws securing the control box, then 
gently pull out the control box. Remove the control box cover.
7) Plug the unit back in. Place the power switch in the "ON" position.
8) 
Fill Cycle – LF/S and UF/S open, BCH and WV energize. LF/S closes. Nothing 
happens at this time. Reservoir continues to fill until UF/S closes. 
Diagnosis: Check that WV fills the reservoir. If not, check water supply line shut-off 
valve, water filters, WV screen, power switch, and BC assembly. See "IV.C. Bin Control 
Check." Check 115VAC to WV. Check WCR terminal #2 (GY wire) to a neutral (W wire) 
for 115VAC. If 115VAC is not present, WCR is either energized or bad. If WCR is 
energized, check F/S. See "IV.D.1. Float Switch Check." If 115VAC is present, check 
for continuity through WV solenoid. If open, replace WV. Check that UF/S closes when 
reservoir is full. If not, check F/S. See "IV.D.1. Float Switch Check."
9) 
Freeze Cycle – UF/S closes. BCH remains energized. WCR, TDR, GM, FM, CR, and 
Comp energize. WV de-energizes. Ice production starts 4 to 6 minutes after Comp 
energizes depending on ambient and water conditions.   
Diagnosis: Check that WCR, TDR, GM, FM, CR, and Comp energize and WV 
de-energizes. If not, check WCR, TDR, GM external protector, GM windings (check 
when GM is cool), GM capacitor, voltage to FM, FM windings, fan blade binding, 
voltage on CR, PTC relay, voltage on Comp external protector, Comp terminals, Comp 
windings, and WV. If optional drain pump HS-0248 is installed, see "IV.E. Optional Drain 
Pump HS-0248." If GM starts, but the auger does not turn, check the spline coupling 
between the auger and GM.
10) 
Refill/Low Water Safety – As ice is produced, the water level in the reservoir drops 
and UF/S opens. When UF/S opens, a latching circuit through LF/S and WCR keeps 
WCR, TDR, GM, FM, CR, and Comp energized. When LF/S opens, WCR de-energizes, 
cutting power to TDR terminal #5 (O wire) and starting FT. WV energizes. Water fills the 
reservoir, UF/S closes. WCR energizes, restoring power to TDR terminal #5 (O wire) 
and resetting FT. WV de-energizes. If UF/S remains open longer than 90 seconds, 
FT terminates, cutting power to TDR terminal #9 (R wire). GM, FM, CR, and Comp 
de-energize. WV remains energized until UF/S closes.