Hoshizaki Dishwasher JWE-24000CUA-L-25B Manual De Usuario

Descargar
Página de 79
50
E. Thermistor Check
If the error code “H1” “H2” “H3” or “H4” or an abnormal temperature [above 231°F (111°
C) or below -6°F (-21°C)] appears in the display, or the wash tank water boils, check the 
thermistor(s) according to the procedure below. If replacement is required, see “IV.H. 
Removal and Replacement of Thermistor.”
1) Use the “ON/OFF” button on the operation panel to turn off the unit, then turn off the 
dishwasher and booster tank power supplies. Lockout/Tagout to prevent the power supplies 
from being turned back on inadvertently.
2) Remove the front panel, then pull out the control box.
3)  Remove the control box cover, then disconnect the CN7 connector from the control board 
(see “II.F.2. Control Board Layout”).
4) To check the wash tank thermistor, check the resistance across the white wires (#1 and 
#2). To check the booster tank thermistor, check the resistance across the pink wires (#3 
and #4). See the table below for proper resistance and temperature relations.
Temperature [°F (°C)]
Resistance [kΩ]
194 (90)
4.30 to 4.62
176 (80)
5.87 to 6.38
158 (70)
8.13 to 8.96
140 (60)
11.5 to 12.8
104 (40)
24.3 to 28.0
68 (20)
56.3 to 67.1
32 (0)
145.6 to 180.6
5)  If any problem is found, replace the thermistor according to “IV.H. Removal and Replacement 
of Thermistor.”