Honeywell Galaxy 3-48C Instruccion De Instalación

Descargar
Página de 90
Galaxy 3 Series Installation Manual
5-3
Configuring a MAX
3
 Reader into the System
MAX
readers can only be configured into the Galaxy system from engineer mode.
Access engineer mode.Wire the MAX
as per the instructions given in Figures 5-1 or 5-2
The MAX
reader must be assigned as either an On-Line or a Stand-Alone module using option 63.2.2 =
OPTIONS.MAX.MAX Address:
0 =
On-Line: The MAX
is fully integrated with the Galaxy system and communicates via the AB line,
sharing system resources and facilities.
1 =
Standalone (default): The MAX operates as an entirely independent unit.  The Galaxy does not
monitor the MAX
3
 for alarms, tampers or power failure.
Configuring as On-Line MAX
3
1.
Connect power to the MAX
3
 as per Figure 5-1.
2.
Ensure that the MAX mode is enabled (option 63.2.1 = OPTIONS.MAX.MAX Mode).
3.
Select option 63.2.2 = OPTIONS.MAX.MAX Address and press the ent key; the Galaxy panel
may prompt (depending on model) for the AB line (1 – 4)) that is to be searched; select the line and
press the ent key. The Galaxy searches for the MAX
3
 with the highest address. New MAX
3
 readers
are addressed as 8 (standalone) by default.
4.
Only if adding a new MAX
3
 reader: On locating the MAX
3
 address, the keypad prompts for the
OPERATING MODE of MAX
3
 to be assigned: select 0 = On-Line and press the ent key.
NOTE: If reprogramming an existing stand-alone reader, the system automatically selects the On-
Line operating mode.
The MAX
can then be readdressed.  The keypad displays the current address of the MAX
3
 and the range of
valid addresses.  Enter the new MAX
3
 address and press the ent key; the Galaxy then reprograms the ad-
dress of the MAX
3
.  The keypad indicates the old and new MAX
3
 addresses and the status of the reprogram-
ming.
All new MAX
3
 readers default to address 7.
NOTE: It is recommended that when adding a reader, it is addressed as the lowest available number on the
line.
When the reprogramming is complete the MAX
3
 bleeps, the LEDs on the MAX
3
 switch off and the keypad
display returns to 2 = MAX Address.
5.
Exit engineer mode - engineer code + esc:  the keypad displays the message 1 MOD. ADDED -
esc=CONTINUE.  LED 2 on the MAX
3
 reader switches on.  Press the esc key; the keypad
returns to the unset banner.
If this message is not displayed, the MAX
3
 reader is not communicating with the control panel
and has not been configured into the system (LED 2 does not switch on).
NOTES:
1. The MAX
3
 reader will not operate until engineer mode is exited and the reader is configured into the
system.
2. All MAX
3
 doors must be closed, otherwise engineer mode cannot be exited.
6.
The on-line MAX
3
 reader is now configured into the system.
Configuring MAX
3