Fan And Heater
Hub Bolt Torque Requirement for Fan Blades
FAN SERVICE
A.  14" 1HP.............................................50 ft. lbs. (Trantorque)
B.  18"-1.5HP..........................................63 ft. lbs. (Trantorque)
C. 24"-7HP through 28" 15HP..............84 ft. lbs. (Trantorque)
D. 24"-7HP through 28" 15HP...............16 ft. lbs. (Browning)