Graco 311163ZAC Bin Evacuation System Manual De Usuario
![Graco](https://files.manualsbrain.com/attachments/1319162103b48ca2e3bc8be98dc4af49773243eb/common/fit/150/50/e6af184f1da33ce12e7a4ef94157d351fbcc741ef980bf1190a6d2679721/brand_logo.jpeg)
Manual Control System
18
311163ZAC
Standard Operation
Loading the Bin
NOTE: When raising and lowering the ram plate, make
sure there are no objects obstructing the unit.
sure there are no objects obstructing the unit.
1.
Open the air shutoff valves for the air controls and
pumps.
pumps.
2.
On the control panel, switch to the RAM UP posi-
tion. If the ram does not elevate, increase the ram
up air regulator pressure on the pneumatic control
panel.
tion. If the ram does not elevate, increase the ram
up air regulator pressure on the pneumatic control
panel.
3.
Move the bin in front of the frame.
4.
Remove the lid from the fluid bin to expose the fluid
bag. If present, open the outer plastic bag and pull it
up over the sides of the bin, exposing the aseptic
inner bag.
bag. If present, open the outer plastic bag and pull it
up over the sides of the bin, exposing the aseptic
inner bag.
5.
Make sure the bag is taut and secure it in place.
6.
Secure the bag sides by using clamps (37) and
tubes (38). See F
tubes (38). See F
IG
. 10.
7.
Load the bin of material into the center of the frame.
Center the bin with the ram plate.
Center the bin with the ram plate.
8.
Initial Startup Only: The frame has spring-loaded
guides to stabilize the bin. Adjust the guides equally
with the screws on all four sides of the bin. Leave
enough space between guides and bin to allow for
removal of the bin.
guides to stabilize the bin. Adjust the guides equally
with the screws on all four sides of the bin. Leave
enough space between guides and bin to allow for
removal of the bin.
9.
Make sure the corner seals (21) are in place.
10. Use corners (39) to help guide the plate. See F
IG
.
10.
11. Switch to the Ram Down position
12. Use the ram plate handles to center the ram plate
inside the bin. Be careful not to pinch the inflatable
seal when it enters the bin.
seal when it enters the bin.
Unloading the Bin
NOTE: When raising and lowering the ram plate, make
sure there are no objects obstructing the unit.
sure there are no objects obstructing the unit.
1.
Follow the Pressure Relief Procedure, page 17.
2.
Ensure seal is deflated and ram is raised.
3.
Unload the bin from the frame.
System Shutdown
Follow the Pressure Relief Procedure, page 17.
Depending on the type of material, it may be best to
deflate the seal and raise the ram plate out of the mate-
rial or keep the ram plate lowered in the bin. Some
materials dry and harden when exposed to air. Cover
materials when they are not being used.
deflate the seal and raise the ram plate out of the mate-
rial or keep the ram plate lowered in the bin. Some
materials dry and harden when exposed to air. Cover
materials when they are not being used.
When raising or lowering the ram plate, keep hands
and body away from ram plate and bin lip.
and body away from ram plate and bin lip.
F
IG
. 10
38*
37*
21
39
TI16235a
* Not used with BESCCC.