Electronic Control System 
24
311163ZAC
Pressure Relief Procedure
1.
Press the STOP button to turn off the pumps.
2.
Shut off the air to the pumps by closing the 
bleed-type air shutoff valve on the pumps’ air supply 
line, or disconnect the air line.
3.
Open all system fluid drain valves that are down-
stream of the pumps.
Initial Startup
This procedure takes you through the settings, adjust-
ments and other steps that must be completed before 
the system is ready for daily operation.
NOTE: Press STOP button at any time to stop the sys-
tem. See F
IG
. 12.
1.
If applicable, fill all the pumps packing nut/wet cups 
1/3 full with a compatible lubricant. Refer to your 
pump manual for details. Do not use Graco Throat 
Seal Lubricant with a sanitary application.
2.
Press POWER button to turn on power to electronic 
control panel.
3.
Turn SEAL to OFF.
4.
Open the air shutoff valves for the pneumatic con-
trols and pumps.
5.
Open the pneumatic control panel door. Check for 
air leaks.
6.
The equipment was tested with fluid. Flush the sys-
tem before loading material. See page 28.
7.
Setting the Pump Slow Timer
The pump slow timer controls the amount of time that 
the pumps will operate at the slow speed for priming the 
pumps. This timer will be active when the plate is in the 
bin, the control is set to AUTO, the seal is inflated and 
the ram is pressurized down.
1.
Press the Timer key to access the timer screens. 
Continue to toggle the key until the PUMP SLOW 
TIMER
 screen appears.
2.
Press the Enter key to enable numerical entry.
3.
Enter the desired set point - Minimum Value: 000, 
Maximum Value: 999. Example (300 = 30 sec).
4.
Press the Enter key a second time to accept the 
value.
Setting the Bin Empty Timer
The bin empty timer controls the amount of time the 
pumps operate at the slow speed for emptying the bin. 
This timer will be activated when the ram is in AUTO 
mode and the proximity switch has been tripped.
1.
Press the Timer key to access the timer screens. 
Continue to toggle the key until the BIN EMPTY 
TIMER
 screen appears.
2.
Press the Enter key to enable numerical entry.
3.
Enter the desired set point - Minimum Value: 000, 
Maximum Value: 999. Example (300 = 30 sec).
4.
Press the Enter key a second time to accept the 
value.
Setting the Vacuum Pump Timer
The vacuum pump timer controls the amount of time the 
vacuum pump operates to assist the deflation of the 
seal. This timer will be activated when the ram is in 
AUTO mode and the proximity switch has been tripped.
1.
Press the Timer key to access the timer screens. 
Continue to toggle the key until the VACUUM PUMP 
TIMER
 screen appears.
2.
Press the Enter key to enable numerical entry.
3.
Enter the desired set point - Minimum Value: 000, 
Maximum Value: 999. Example (300 = 30 sec).
4.
Press the Enter key a second time to accept the 
value.
Trapped air can cause the pump to cycle 
unexpectedly, which could result in serious injury 
from injection, splashing or moving parts. Relieve 
pressure when you stop pumping and before 
cleaning, checking, or servicing equipment.