Maintenance
311163ZAC
29
Cleaning Ram Plate and Seal
1.
Follow thPressure Relief Procedure, page 17 or 
page 24. Keep the air supply to the ram open.
2.
Raise the ram plate.
3.
Engage the manual stop.
4.
Remove the inflatable seal and corner seals from 
the ram plate.
5.
Clean the seals and ram plate with a compatible 
cleaning fluid.
6.
Apply a generous amount of lubricant to the ram 
plate channel and seals.
7.
Install the inflatable seal and corner seals on the 
ram plate. Position the inflatable seal so that the 
seal bottom is angled into the ram plate channel.
To avoid injury, always set manual stop latch to 
Engage position when working under the plate.