Service
311163ZAC
33
Replacing Proximity Switch 
(Electronic Control Models Only)
1.
Follow thBefore Servicing procedure, page 31.
2.
Mark the proximity switch (641) position on its 
bracket (B) to ensure the new switch is installed the 
same. Refer to F
NOTE: Graco recommends 1/4 in. (6.35 mm) space 
between switch and plate (15).
3.
Disconnect the cable from the switch (641).
4.
Remove the two screws, lock washers, and the 
switch.
5.
Secure the new switch to the bracket (B) with the 
screws and lock washers.
6.
Reconnect the cable.
7.
Restart the system and verify the switch operates 
correctly.
Electronic Control Panel Service 
(Electronic Control Models Only)
Follow the Before Servicing procedure, page 31. Con-
sult a qualified electrician to service the control panel.
F
IG
. 17: Proximity Switch
4
641
15
B
TI16238a