Graco 311163ZAC Bin Evacuation System Manual De Usuario

Descargar
Página de 64
Technical Data
311163ZAC
63
BESAxx, BESBxx, BESCxx, BESDxx, BESExx, and BESFxx
Ma
U.S.
Metric
Compressed air requirement
80-100 psi
5.5-7 bar, 0.55-0.7 MPa
Sound data
See your pump manual.
Wetted parts
300 Series stainless steel, buna-N, and
EPDM on the ram plate and seals.
See your pump manual for additional wetted parts.
Pump Outlet
BESAxx, BESBxx, BESCxx, BESExx, BESFxx
2 in tri-clamp
BESDxx
1.5 in tri-clamp
Maximum Working Fluid Pressure
BESAxx, BESBxx, and BESCxx
410 psi
28.3 bar, 2.8 MPa
BESDxx
650 psi
44.8 bar, 4.5 MPa
BESExx and BESFxx
1450 psi
100.4 bar, 10.1 MPa
Fluid Displacement (each pump)
BESAxx, BESBxx, and BESCxx
0.23 gal/cycle
0.87 l/cycle
BESDxx
0.067 gal/cycle
0.25 l/cycle
BESExx and BESFxx
0.14 gal/cycle
0.53 l/cycle
Flow Rate @ 60 cpm
BESAxx
27.6 gpm
104.5 lpm
BESBxx
54 gpm
204.4 lpm
BESCxx
27.6 gpm
104.5 lpm
BESDxx
8 gpm
30 lpm
BESExx
17 gpm
64.3 lpm
BESFxx
34 gpm
128.7 lpm
Pressure Ratio
BESAxx, BESBxx, and BESCxx
4.3:1
BESDxx
6:1
BESExx and BESFxx
10:1
Air Consumption (each pump)
BESAxx, BESBxx, and BESCxx
1.8 scfm per gpm @ 70 psi
0.14 m
3
/minute per lpm
@ 4.8 bar, 0.48 MPa
BESDxx
6 scfm per gpm @ 70 psi
0.17 m
3
/minute per lpm
@ 4.8 bar, 0.48 MPa
BESExx and BESFxx
3.5 scfm per gpm @ 70 psi
0.026 m
3
/minute per lpm @
4.8 bar, 0.48 MPa
Pneumatic Control Panel
Maximum input air pressure
100 psi
7 bar, 00.7 MPa
Maximum up/down ram pressure
75 psi
5.2 bar, 0.5 MPa
Air inlet - air controls
3/4 in npt(f)
Air inlet-pump
1 in npt(f)
Electronic Control Panel
Maximum input air pressure
100 psi
7 bar, 0.7 MPa
Maximum up/down ram pressure
100 psi
7 bar, 0.7 MPa
External power supply