202
A change to this setting on either SM module is automatically updated on the other SM module.
Table 7–3
shows the temperature and voltage thresholds for each alarm and what to do to resolve the 
problem. 
Table 7–3
.
Alarm thresholds
Alarm threshold
What to do when the alarm sounds
Galaxy 65 internal temperature
• Warning: 0°C to 4°C and 
66°C to 70°C
• Shutdown: <0°C and >70°C
• Check the Disk Array Administrator software to confirm 
what the alarm means. See 
D.2, ”Displaying the Event 
Log”, on page 154
.
• Check the ambient temperature and lower it, if needed. 
Ambient temperature should be less than 45°C.
• Check that the Galaxy 65 Subsystem has good airflow 
clearance. The Galaxy 65 Subsystem requires airflow 
clearance on all sides, except the bottom and top.
• Check that the internal fans are running. The fans are in 
the Power Managers.
Galaxy 65 CPU temperature
• Warning: 0°C to 4°C and 
91°C to 100°C
• Shutdown: <0°C and >100°C
• Same as above.
VCC voltage
• Warning: 5 V -10% to -8% and +8% 
to +10%
• Shutdown: 5 V <-10% and >+10%
• Check the Disk Array Administrator software to confirm 
what the alarm means. See 
D.2, ”Displaying the Event 
Log”, on page 154
.
• If it is a warning alarm, let the Galaxy 65 Subsystem 
continue to operate. 
• If it is a shutdown alarm, see which SM module is 
showing the alarm. If only one SM module shows the 
alarm, replace that SM module. If it is both, you must 
troubleshoot the Power Supply/Cooling modules.