Galaxy Metal Gear 65 Manual De Usuario

Descargar
Página de 258
Galaxy 65 Troubleshooting
63
7.4.1 System Faults
7.4.2 Power Supply/Cooling Faults
Symptom
Cause
Action
The SYSTEM LED will 
illuminate AMBER on 
the LRC
Audible Alarm sound
The ESI processor 
has detected an 
internal fault (e.g. 
failure of an 
internal 
communications 
path) 
Check for other AMBER LED indications on the 
Power Supply/Cooling modules. If there is a 
PSU error present there may be a 
communications problem with that Power 
Supply/Cooling module. Remove and then re-fit 
the module, if the problem persists then change 
the module.
Check for other AMBER LED indications on the 
drives carriers. If none are evident then there 
may either be an ESI processor problem or a 
Backplane problem. 
Change the Ops Panel module (see 
7.12.2
).
Symptom
Cause
Action
Ops Panel 
FAULTLED AMBER
An AMBER LED on 
one or more Power 
Supply/Cooling 
Modules.
Audible Alarm 
Sounding.
Any power 
fault.
A fan failure.
A thermal 
condition 
which could 
cause PSU 
overheating.
Check Power On/Off Switch on rear of Power 
Supply/Cooling module is switched ON.(not 
accessible on later models)
Check AC Mains Connections to Power Supply/
Cooling module is live.
Disconnect the Power Supply/Cooling module 
from mains power and remove the module from 
the system, Re-install: if problem persists, 
replace Power Supply/Cooling Module.
Reduce the ambient temperature.