Galaxy Metal Gear 65 Manual De Usuario

Descargar
Página de 258
Galaxy 65 User Guide
74
7.12.4 Insertion/Removal of SFP Modules
The LRC Module is fitted with four Small Form Factor (SFP) GBIC modules. Replacement of these 
modules should be performed in accordance with the following procedure:
1
Press down firmly on the removal tab located at the bottom of the cable.
2
 Remove the module by firmly gripping each side of it.
Caution
If the module cannot be easily removed do not use force. Repeat step 
1
.
7.12.5 Battery Replacement
Battery Safety
• The battery should only be replaced by a trained technician.
•  The battery should be disposed of in accordance with the manufacturer’s instructions and National 
regulations.
Warning
Risk of explosion if battery assembly is replaced by an incorrect type. The battery assembly must 
only be replaced with a battery assembly of the following type, which contains current limiting 
and temperature sensing devices:
• Battery Assembly SM
Feature Code: Galaxy 65-Batt
Caution
 If this equipment is used in a manner not specified by the manufacturer, the protection provided by the 
equipment may be impaired.
ESD Precautions
It is recommended that you fit and check a suitable anti-static wrist or ankle strap and observe all 
conventional ESD precautions when handling plug-in modules and components. Avoid contact with 
backplane components and module connectors, etc.
Data Security
Caution
This procedure will remove all data from the cache.
Tools Required
None
Removal/Replacement Procedure
1
 Unplug the battery flying lead from the RAID controller.
2
 Release the battery assembly by squeezing the two latches (shown in 
Figure 7–8
) with thumb and 
forefinger and slide the assembly out of the LRC module. 
3
Fit the new battery assembly by squeezing the two latches and sliding it into the LRC module. 
4
Release the two latches and reconnect the battery flying lead to the RAID controller.
5